COMM2_baudrate

Description: Serial COM2 port speed baud rate.

Possible values:

  • 460800, 230400, 115200, 57600, 38400, 19200, 9600, 4800, 2400, 1200, 600, 300
  • Default value: 115200

Additional notes:

  • Configuration of the device connected to the modem and MTX-Tunnel must be same

COMM2_autorts

Description: This parameter configures the COM2 serial port to have hardware flow control (RTS line). If enabled (value=”on”) hardware flow control will be used; otherwise (value=”off”), no hardware flow control will be used.

Possible values:

  • on, off
  • Default value: off

Additional notes:

  • Configuration of the device connected to the modem and MTX-Tunnel must be the same
  • Use the same value in the COMM_autorts parameter
  • This parameter can only be used in the MTX-IND terminals the rest of the models do not have flow control available in the secondary port

COMM2_autocts

Description: This parameter configures the COM2 serial port to have hardware flow control (CTS line). If enabled (value=”on”) hardware flow control will be used; otherwise (value=”off”), no hardware flow control will be used.

Possible values:

  • on, off
  • Default value: off

Additional notes:

  • Configuration of the device connected to the modem and MTX-Tunnel must be the same
  • Use the same value in the COMM_autorts parameter
  • This parameter can be used only in the MTX-IND terminal modems. Other MTX-Terminal modems do not have flow control in the second serial port

COMM2_bitsperchar

Description: COM2 serial port number of bits per character.

Possible values:

  • 7, 8
  • Default value: 8

Additional notes:

  • Configuration of the device connected to the modem and MTX-Tunnel must be the same
  • This parameter can only be used in the MTX-IND mdoem terminals. The rest of the models do not have flow control in the secondary port

COMM2_stopbits

Description: Number of stop bits per character in COM2 serial port.

Possible values:

  • 1
  • Default value: 1

Additional notes:

  • Configuration of the device connected to the modem and MTX-Tunnel must be the same
  • This parameter can only be used in the MTX-IND modem terminals. The rest of the models do not have flow control in the secondary port. From version 7.27, 2 bits of data can be specified. 2 bit data communications can be slower than those of 1 stop bit, especially with large volume data communications. 1 stop bit is recommended when possible

COMM2_parity

Description: Parity used in COM2 serial port data communication.

Possible values:

  • none, odd, even
  • Default value: none

Additional notes:

  • Configuration of the device connected to the modem and MTX-Tunnel must be the same
  • This parameter can only be used in the MTX-IND modem terminals. The rest of the models do not have flow control in the secondary port